Today. I’m going to talk more about installing accessories here at roofing and Siding Smith’s your roofer Greenville Texas. Before the siding itself can be hung. A number of accessories must be installed first including starter strips, corner posts, window flashing, trim J, channels over the roof lines and around openings, outside and inside corner posts. Uh, it’s a water resistant material that should be used to flash the inside and outside corners. A minimum of 10 inches on each side before installation of the corner posts inside corner posts can be a single or double J channel or a factory formed inside corner. You need to put the corner post in position, allowing a quarter inch gap between the top of the post and Eve or soffit position and nail at the top of the upper slot on both sides.
In the corner posts leaving a gap of approximately one 32nd between the nail heads in the corner posts, the corner posts hang from these nails. The balance of the nailing should be in the center of the slot eight inches to 12 inches apart. Again, leaving one 32nd between the nail head and the corner. Post your roofer Greenville Texas. This allows for expansions and contractions to occur at the bottom. The corner posts should extend three quarters of the niche below the starter strip. Make sure the posts are plum and square to the wall. Cut away any exposed nail hymns at roofing and siding. Smith’s your roofer Greenville Texas. If more than one length of corner post is required, overlap the upper piece over the lower piece by cutting away an inch of the nailing flange on the top piece.
Overlap three quarters of an inch, allowing a quarter inch for expansion. This method will produce a visible joint between the two posts but will allow water to flow over the joint. Reducing the chance of water infiltration here at roofing and siding Smith’s your roofer Greenville Texas.
When you cap a corner, posts the corner posts on the home with a second story overhang. Need to be kept by making the cuts shown. Follow the created over each other as indicated. Drill a one eighth inch hole in the center through both layers of the vinyl and install a popper of it to hold them in place.
Cut a notch in both layers to allow clearance for the corner for your starter strip. In order for the siding to be installed properly in a level fashion, the starter strip at the bottom of the wall has to be level. You need to determine the lowest point of the wall. That will be sad. If from point, measure up a quarter inch less than the width of the starter strip and partially drive a nail at one corner. Attach a chalk line, go to the next corner and pull that line tight. Make sure the lines level by using a line level or four foot level. You need to snap the chalk line and repeat the procedure around the entire house.
That way you know where your starter strip needs to be at the bottom of the wall before you get started. If this is level, then it’ll keep you from running your side and crooked here at roofing and siding. Smith’s your roofer Greenville Texas and optional method to determine the position and the starter strip in new construction in some resetting applications. Measure down from the soffit at one corner of the house to the top of the foundation and subtract a quarter inch less the width of the starter strip. Make a Mark on the wall and record the measurement. Then take the measurement and transfer it to the corner of the wall. Snap a chalk line in between the corners at the marks.
Repeat that all the way around the house. Also using a chalk line as a guide, installed the top edge of the starter strip using the chalk line, nailing at 10 inches at 10 inch intervals. Allow space for the corner posts, J channels and other methods here at roofing and siding. Smith’s your roofer Greenville Texas, your siding contractor Greenville Texas, your window replacement contractor Greenville Texas, and your gutter installer. Greenville, Texas. Keep the ends of the starter strips at least a quarter inch apart to allow for expansion. Now on the center of the starter strip nailing slots for insulated siding. The starter strip needs to be spaced away from the wall to accommodate for the thickness of the backing of the siding and you need to follow all the manufacturer’s guidelines on that.
Now we’re going to talk about windows, doors and roof lines here at roofing and siding Smith’s your roofer Greenville Texas and flashing new window installations. If you’re installing a new window and flashing, refer to the manufacturer’s instructions for proper flashing installation method for the window type and wall configuration on that particular project. If you’re going to flash a previously installed nail fin windows, you need to install it without flashing. The following instructions should be followed. Apply continuous bead of sealant to the nailing flange of the seal and a manner that covers the nail and nail slots.
Apply a minimum of nine inch of a nine inch wide horizontal seal flashing level with the bottom edge of the existing window by pressing the flash, the flashing into the sealant at at its topic. It’s got the seal flashing long enough to extend a minimum of nine inches beyond each jam. Fast in the seal flashing at the bottom and side edges, roofing and siding Smiths, your roofer Greenville Texas. Apply continuous bead of sealant to the nailing flange of the jams in a manner that covers the nail nails and nail slots. Continue the bead of sealant at the jams vertically, a minimum of eight and a half inches above the head of the window to allow for beating for betting. The top portion of the jam flashing into the sealant in the next step.
After that, install the jam flashing by pressing the wind, pressing the flashing into the sealant beads at the window jams. Extend the bottom edge of the jam. Flashing approximately half an inch short of the seal flashing edge and extend the top edge approximately eight and a half inches beyond the head of the window where the head of the flashing will be placed. Next, Fasten the jam. Flashing along the edges. Furthermost from the window. Roofing and siding Smiths.